tached to the system, will only slow down the system operation slightly. When this toggle is
ÔONÕ, you will see the LEDs on the front of all the dumb PA Stations flash once each second
as the clocks are updated.

h) set time:
i)

set date:

These do pretty much what you would expect them to do. Other than time stamping,

the clock and calendar arenÕt used for anything in the system. The seconds are reset to zero
when you enter the minutes.

j)

allow zone stepping:

This toggle when ÔONÕ will not allow any dumb PA stations to open any PA zone which is

currently being used by any other PA station. If enabled, this will also generate an error mes-
sage on the terminal and printer output from the MA-100 PA Master. Smart PA Stations can
individually enable or disable their ability to step on zones which are being used by other PA
stations.

Conditions to Print:
p) print all errors:
q) print all openings:
r)

print all closings:

s)

print all others:

Conditions to Display
t)

display all errors:

u) display all openings:
v)

display all closings:

w) display all others:

These toggles control how much data will be sent to the printer or terminal. The various

messages are defined as follows:

1)

errors = any trouble messages from the PA master or PA Stations.

2)

openings = any PA zone or local request has been received.

3)

closings = any PA zone or local request has been released.

4)

others = volume zone, mute zone, or any other special request from the PA stations.

z)

unmute on boot up:

When this toggle is on, all volume zones will be set to their maximum levels and all mute

zones will be cleared when ever the MA-100 resets.

x)

eXit:

This returns you to the first menu.

G) volume zone #1 maximum limit:
H) volume zone #2 maximum limit:
I) volume zone #3 maximum limit:
J) volume zone #4 maximum limit:
K) volume zone #5 maximum limit:
L) volume zone #6 maximum limit:
M) volume zone #7 maximum limit:
N) volume zone #8 maximum limit:
O) volume zone #1 minimum limit:
P) volume zone #2 minimum limit:
Q) volume zone #3 minimum limit:
R) volume zone #4 minimum limit:
S) volume zone #5 minimum limit:
T) volume zone #6 minimum limit:
U) volume zone #7 minimum limit:
V) volume zone #8 minimum limit:

Volume Zone Limits: These commands allow you to limit the range of adjustment for the

eight analog VOLUME CONTROL outputs when adjusted from a PA Station. This allows you to