INTELLIGENT PA SYSTEM HARDWARE CONFIGURATION:

Each MA-200, including the one inside the MA-100, must be addressed before it is connected and

turned on. A 5 position dipswitch or a rotary switch (plus a 2 position dipswitch) on the back of each unit
is used to set which address the PA stations and Local Outputs on each MA-200 will respond to. With up
to 32 MA-200Õs attached to the system, the following are all of the possible settings for these switches:

MA-100

PA Station

or

and

MA-200

5

4

3

2

1

Rotary Sw

1

MA-100/200 Outputs

1

on

on

on

on

on

0

00 through 07

2

on

on

on

on

open

0

08 through 0F

3

on

on

on

open

on

1

10 through 17

4

on

on

on

open

open

1

18 through 1F

5

on

on

open

on

on

2

20 through 27

6

on

on

open

on

open

2

28 through 2F

7

on

on

open

open

on

3

30 through 37

8

on

on

open

open

open

3

38 through 3F

9

on

open

on

on

on

4

40 through 47

10

on

open

on

on

open

4

48 through 4F

11

on

open

on

open

on

5

50 through 57

12

on

open

on

open

open

5

58 through 5F

13

on

open

open

on

on

6

60 through 67

14

on

open

open

on

open

6

68 through 6F

15

on

open

open

open

on

7

70 through 77

16

on

open

open

open

open

7

78 through 7F

17

open

on

on

on

on

8

80 through 87

18

open

on

on

on

open

8

88 through 8F

19

open

on

on

open

on

9

90 through 97

20

open

on

on

open

open

9

98 through 9F

21

open

on

open

on

on

A

A0 through A7

22

open

on

open

on

open

A

A8 through AF

23

open

on

open

open

on

B

B0 through B7

24

open

on

open

open

open

B

B8 through BF

25

open

open

on

on

on

C

C0 through C7

26

open

open

on

on

open

C

C8 through CF

27

open

open

on

open

on

D

D0 through D7

28

open

open

on

open

open

D

D8 through DF

29

open

open

open

on

on

E

E0 through E7

30

open

open

open

on

open

E

E8 through EF

31

open

open

open

open

on

F

F0 through F7

32

open

open

open

open

open

F

F8 through FF

The ÔOPENÕ position on each switch is towards the top of the case.

The MA-100 is usually addressed as #1, but can be set for any address desired so long as it doesnÕt

conflict with any MA-200.

The four serial ports on the MA-100 can each be configured to different baud rates using wire wrap

G

ILDERFLUKE

& C

O

. ¥ 205 S

OUTH

F

LOWER

S

T

. ¥ B

URBANK

, C

ALIF

. 91502-2102 ¥ 818/840-9484 ¥

FAX

818/840-9485

8 of 35

1

With the MA-100/200s with the address set with a rotary switch, the #2 dipswitch is set as shown for

the #1 switch column.

Advertising