2.6.4

Non-isolated External I/O Specification


Input Part

Item Specification

Number of inputs

8 points

Input voltage

24 VDC

 10%

Input current

7 mA/1 circuit

Operation voltage

ON voltage --- 18 V min.
OFF voltage --- 6 V max.

Isolation method

Not isolated


Output Part
There are two specifications for the output part, namely Group 1 and Group 2.
Group 1: Output circuit based on TD62084 (or equivalent) (8 points)

Item Specification

Signal name

Complete positions 1, 2, 4, 8, positioning complete, home return
complete, zone, alarm

Rated load voltage

24 VDC (built-in flywheel diode)

Rated load current

40 mA/1 point

Recommended load current

20 mA/1 point

Leak current

0.1 mA (max.)

Residual voltage

3.1 V/40 mA (max.)

Isolation method

Not isolated

Overcurrent protection

47-

, 0.1-W fuse resistance


Group 2: 100-mA output circuit based on MOSFET (2 points)

Item Specification

Signal name

Emergency stop, moving

Maximum output voltage

60 V (peak) (Open drain, no flywheel diode)

Maximum load current

100 mA/1 point

Residual voltage

1.1 V/100 mA

Isolation method

Not isolated

Overcurrent protection

10-

, 0.1-W fuse resistance

Advertising