3 movement after power on (standard type), Movement after power on (standard type), P l c – IAI America RCS-E User Manual

Page 57

Advertising
background image

41

4.3

Movement after Power On (Standard Type)

Example of use in operation) After the power is turned on, move the actuator to the position 150 mm from the

home at a speed of 200 mm/sec.

Position-data table (Field(s) within thick line must be entered.)

No. Position

Speed

Acceleration/

deceleration

Push Positioning

band

Acceleration

only MAX

0

0 100

0.3 0 0.1 0

1

150

200

0.3 0 0.1 0

RCS controller












































P

L

C

[7] [4]

[3]







[2]

[1]

[10]





[9] [5]

[8]





[11] [6]

PIO

Signal name

Start

Command position 1

Command position 2

Command position 4

Command position 8

Pause

Reset

Servo ON

Completed position 1

Completed position 2

Completed position 4

Completed position 8

Position complete

Home return completion

Zone

Alarm

Emergency stop

Moving

Category

Input

















Output

Reference flow

Power ON

Select/enter command position 1.

[1]

[2]

[3]

[4]


[5]

[6]


[7]



[8]



[9]

[10]

[11]

Start input ON

Home return starts.

Position complete output OFF

Moving output ON

Start input OFF

Home return completes.

Home return completion output ON

Movement to position 1 starts.

Position complete output turns ON 0.1 mm
before position 1.

Completed position 1 is output.

Moving output OFF

Movement to position 1 completes.

With the absolute specification, the home
return completion signal will turn ON after
the power is turned on, and the actuator will
move directly to position 1 without
performing home return.

Servo ON input ON

Pause input ON

Advertising