79

Example of Basic RCS Positioning Sequence

An example of basic sequence is given below for reference when creating an RCS positioning sequence.

indicates a PIO signal of the RCS controller.



















































(Completed position decoding circuit)
Positioning complete

Completed position code

(Not less than the
PLC’s scan time)

Waiting for completed position to be read





Completed position 1



Completed position 2

Completed position 3

Completed position 4

Completed position 5



Homing start pulse


Homing start pulse, auxiliary





Position 1 (home) poisoning start pulse



Position 1 (home) poisoning start pulse, auxiliary






Position 1 (home) poisoning start, auxiliary











Position 1 (home) start confirmation





Position 1 (home) positioning complete

To be created for the number of positions.

(Position 1 positioning circuit: When position 1 is home.)

Homing request

Homing request

Position 1
positioning start
request

Position 1
positioning start
request

Positioning start request signals are sent as pulses so that one start signal
will be sent for each positioning operation.

Homing complete

Current positioning
completed position

Start signal

Moving signal

Next positioning
start auxiliary
signal

Completion of positioning to the command position is confirmed.