1. Precautions for Use

11. Precautions for Use

11.1 Setting the Acceleration/Deceleration

Set the acceleration/deceleration using the graphs below as a reference.

(1) PTP operation (Set using the SEL language commands ACCS and DCLS.)

IX-NNN50

……H/60……H/70……H/80……H, IX-NNW50……H/60……H/70……H/80……H,

IX-NNC50

……H/60……H/70……H/80……H

Acceler

ation deceleration (%)

Acceler

ation deceleration (%)

IX arm length 500/600

Reference settings for PTP

acceleration/deceleration

IX arm length 500/600

Reference duties for PTP

continuous operation

Maximum

setting range

Reference range for

continuous operation

Reference range of duty for

continuous operation duty

Duty (%)

Inertial moment (kg-m)

Duty (%) = (Continuous operation /
(Continuous operation + Stopping time)) / 100

Mass of carrying load (kg)

Axis 4 (rotation

axis) only

Acceler

ation deceleration (%)

Acceler

ation deceleration (%)

IX arm length 700/800

Reference settings for PTP

acceleration/deceleration

IX arm length 700/800

Reference duties for PTP

continuous operation

Maximum

setting range

Reference range for

continuous operation

Reference range of duty for

continuous operation duty

Duty (%)

Inertial moment (kg-m)

Duty (%) = (Continuous operation /
(Continuous operation + Stopping time)) / 100

Mass of carrying load (kg)