7.2

MOTOR HORSEPOWER (J2) – Set Jumper J2 to the corresponding position

for the motor being used. See Figure 10.

7.3

AUTOMATIC OR MANUAL START AND RESET SELECTION (J3) –

See Figure 11, on page 17.

7.3.1 WARNING! Automatic Start and Reset – Jumper J3 is factory set

to the “AUTO” position to automatically start the drive when the

power is applied and the On/Off AC Line Switch is set to the “ON”

position. The drive will also automatically restart after an

Undervoltage or Overvoltage Fault has cleared.

16

Drive

Operating

Condition

Description

Run Relay Operation

(J5 Installed in “RUN” Position)

(Factory Setting)

Fault Relay Operation

(J5 Installed in “FLT” Position)

Normally Open

Contact

Normally Closed

Contact

Normally Open

Contact

Normally Closed

Contact

Power Off

Main Power Disconnected

Open

Closed

Open

Closed

Run Mode

1

Normal Drive Operation

Closed

Open

Closed

Open

Stop Mode

2

Selected by Operator

Open

Closed

Closed

Open

Fault

3

Drive Tripped

Open

Closed

Open

Closed

TABLE 5 – DRIVE OPERATING CONDITIONS & RUN/FAULT RELAY CONTACT STATUS

Notes: 1. Run Mode is selected with the optional Forward-Stop-Reverse Switch or with the jumper installed in CON2 (jumper installed in the “F-
S” position for forward direction (factory setting) or jumper installed in the “R-S” position for reverse direction). 2. Stop Mode is selected using
the optional Forward-Stop-Reverse Switch. 3. I

2

t, Short Circuit, Undervoltage, Overvoltage.

7

SETTING SELECTABLE JUMPERS

The drive has customer selectable jumpers which must be set before the drive can be used. For the location of

jumpers, see Figure 4, on page 12. Disconnect the AC line before changing position of Jumpers.

7.1

AC LINE INPUT VOLTAGE (J1) – The drive is factory set for 208/230 Volt AC line input(Jumper J1 not

installed). For 115 Volt AC line input, install Jumper J1. See Figure 9.

208/230 Volt AC Line Input

(Jumper J1 not Installed (Factory Setting))

115 Volt AC Line Input

Jumper J1 Installed

2

115V

AC

J1

A

J1-A

B

J1-B

115V

AC

J1

J1-A

A

J1-B

B

Notes: 1.

The drive is factory set for 208/230 Volt AC line input (Jumper J1 not installed). For 115 Volt AC line input, install Jumper

J1 (supplied).

2.

Jumper J1 is supplied in the hardware bag.

FIGURE 9 – AC LINE INPUT VOLTAGE SELECTION

1

FIGURE 10 – MOTOR

HORSEPOWER SELECTION

J2

3/4

1/4
1/8

1/2

1HP

Advertising