KB Electronics KBMA-24DF User Manual

Page 9

Advertising
background image

9

Description

Specification

Factory Setting

115 Volt AC Line Input Voltage Operating Range (Volts AC)

1

115 (±15%)

208/230 Volt AC Line Input Voltage Operating Range (Volts AC)

1

208 (-15%) / 230 (+15%)

2

Maximum Load (% Current Overload for 1 Minute)

150

Horsepower Selection (HP) (J2)

1/8, 1/4, 1/2, 3/4, 1

1

Carrier, Switching Frequency (kHz)

16, 8

Output Frequency Resolution (Bits, Hz)

10, .06

Minimum Speed Trimpot (MIN) Range (% Frequency Setting)

0 – 40

0

Maximum Speed Trimpot (MAX) Range (% Frequency Setting)

70 – 110

100

Acceleration Trimpot (ACCEL) and Deceleration Trimpot (DECEL) Range (Seconds)

.3 – 20

1.5

Slip Compensation Trimpot (COMP) Range at Drive Rating (Volts/Hz)

0 – 3

1.5

Current Limit Trimpot (CL) Range (% Full Load)

40 – 200

160

Motor Frequency Setting (Hz) (Jumper J5)

50, 60

60

Output Frequency Multiplier (1X, 2X) (Jumper J4)

3

1, 2

1

Minimum Operating Frequency at Motor (Hz)

0.3

Speed Range (Ratio)

60:1

Speed Regulation (30:1 Speed Range, 0 – Full Load) (% Base Speed)

4

2.5

Overload Protector Trip Time for Stalled Motor (Seconds)

6

Undervoltage/Overvoltage Trip Points for 115 Volt AC Line Input (±5%) (Volts AC)

1

76 – 141

Undervoltage/Overvoltage Trip Points for 208/230 Volt AC Line Input (±5%) (Volts AC)

1

151 – 282

Run/Fault Relay Output Contact Rating (Amps at 30 Volts DC, 125 Volts AC, 250 Volts AC)

1, 0.5, 0.25

Operating Temperature Range (°C / °F)

0 – 45 / 32 – 113

Notes: 1. Do not operate the drive outside the specified AC line input voltage operating range. 2. The drive is factory set for 208/230 Volt AC line input
(Jumper J1 not installed). For 115 Volt AC line input, install Jumper J1 (supplied). See Figure 9, on page 16. 3. Allows the motor to operate up to two times
the rated RPM. Constant motor horsepower will result when operating the drive in the “2X” mode above the motor nameplate rated RPM. 4. Dependent on
motor performance.

TABLE 2 – GENERAL PERFORMANCE SPECIFICATIONS

Model

Part

No.

AC Line Input

Fuse or Circuit

Breaker Rating

(Amps)

Output

Net Weight

Volts AC

(50/60 Hz)

Phase

(φ)

Maximum

Current

(Amps AC)

Voltage

Range

(Volts AC)

Maximum Continuous

Load Current

(RMS Amps/Phase)

Maximum

Horsepower

(HP (kW))

Lbs.

kg

KBMA-24D

9533

115

1

16

20

0 – 230

3.6

1 (.75)

2.42

1.09

208/230

1

1

10

15

KBMA-24DF

2

9534

115

1

16

20

0 – 230

3.6

1 (.75)

2.48

1.12

208/230

1

1

10

15

TABLE 3 – ELECTRICAL RATINGS

Notes: 1. The drive is factory set for 208/230 Volt AC line input (J1 not installed). For 115 volt AC line input, install Jumper J1 (supplied). See Figure 9, on
page 16. 2. Model KBMA-24DF contains a built-in AC line Class A RFI (EMI) filter which meets the CE Council Directive 89/336/EEC Industrial Requirement.

Advertising