• Motor Horsepower Selection Jumper – Allows the drive to be used on a wide range of motor horse-

power (1/8, 1/4, 1/2, 3/4, 1 HP) without recalibration or programming.

• Diagnostic LEDs – PC board mounted LEDs for Power On (ON), Drive Status (ST), and Overload (OL).

• Run/Fault Relay Output Contacts – Can be used to turn on or off equipment or to signal a warning if

the drive is put into the Stop Mode or a fault has occurred.

• Barrier Terminal Blocks – Facilitate wiring of AC line, motor, ground (earth) and Run/Fault Relay Output

Contacts.

• On/Off AC Line Switch – Panel mounted. Used to turn the power on or off to the drive.

• Pilot Light – Panel mounted. Indicates that power is applied to the drive and the On/Off AC Line Switch

is set to the “ON” position.

• Main Speed Potentiometer – Panel mounted. Provides adjustment of motor speed.

• Jumper Selection of Drive Output Frequency – Increases the motor speed up to two times the rated

RPM.

• Compatible with GFCIs (with optional software).

3.2

PERFORMANCE FEATURES

• Power Start™ – Provides more than 200% starting torque which ensures startup of high frictional loads.

• Slip Compensation with Static Auto-Tune and Boost – Provides excellent load regulation over a wide

speed range.

• Speed Range – 60:1

3.3

PROTECTION FEATURES

• Motor Overload (I

2

t) with RMS Current Limit – Provides motor overload protection which prevents

motor burnout and eliminates nuisance trips.*

• Electronic Inrush Current Limit (EICL™) – Eliminates harmful inrush AC line current during startup.

• Short Circuit – Shuts down the drive if a short circuit occurs at the motor (phase-to-phase).

• Regeneration – Eliminates tripping due to bus overvoltage caused by rapid deceleration of high

inertial loads.

• Undervoltage and Overvoltage – Shuts down the drive if the AC line input voltage goes above or below

the operating range.

• MOV input transient suppression.

• Microcontroller self monitoring and auto-reboot.

*UL approved as an overload protector for motors.

3.4

SELECTABLE JUMPERS (See Section 7, on pages 16 – 18.)

• AC Line Input Voltage Selection (115/230 Volts AC) (J1)

• Motor Horsepower (1/8, 1/4, 1/2, 3/4, 1 HP) (J2)

• Automatic or Manual Start and Reset (J3)

• Frequency Multiplier (1X, 2X) (J4)

• Motor Frequency (50/60 Hz) (J5)

• “Run” or “Fault” Output Relay Operation (J6)