24

Installation

SPEEDMASTER™ OPERATION MANUAL

Figure 13. 174709 Connections

115 OR 230

VAC LINE

VOLTAGE INPUTS

EARTH GROUND

(GREEN SCREW)

A2

A1

115 VAC

230 VAC

MOTOR

ARMATURE

Figure 12. Cased Drive Connections

1

2

3

4

5

6

7

+

-

EARTH GROUND

(GREEN SCREW)

115

VAC

230

VAC

MOTOR

ARMATURE

WITH 115 VAC INPUT:
CONNECT TO TERMINAL 1 FOR 50 VOLT FIELD.
CONNECT TO TERMINAL 6 FOR 100 VOLT FIELD.

WITH 230 VAC INPUT:
CONNECT TO TERMINAL 1 FOR 100 VOLT FIELD.
CONNECT TO TERMINAL 6 FOR 200 VOLT FIELD.

MOTOR FIELD

(SHUNT WOUND

MOTORS ONLY)

NOTE: DO NOT make

any connections to

terminal 7 if using a

permanent magnet motor.

NOTE

: If using a shunt

wound motor with 174709
refer to Table 2 for field
connections.