SPEEDMASTER™ OPERATION MANUAL

Warning

Dangerous voltages exist on the drive when it is powered.
When possible, disconnect the drive while troubleshooting.
High voltages can cause serious or fatal injury.

ƽ

Before troubleshooting

Perform the following steps before starting any procedure in this
section:

•

Disconnect AC line voltage from the drive.

•

Check the drive closely for damaged components.

•

Check that no conductive or other foreign material has
become lodged on the printed circuit board.

•

Verify that every connection is correct and in good
condition.

•

Verify that there are no short circuits or grounded
connections.

•

Check that the voltage switch settings match the AC line
and maximum armature output voltages.

•

Check that the drive’s rated armature outputs are consistent
with the motor ratings.