Symptom possible causes suggested solutions – LEESON SCR Thyristor Motor Control User Manual

Page 59

Advertising
background image

53

Troubleshooting

SPEEDMASTER™ OPERATION MANUAL

Symptom

Possible

Causes

Suggested

Solutions

Motor pulsates or
surges under load

On non-reversing
drives, motor runs in
the opposite direction

Motor will not stop
when the speed adjust
potentiometer or
reference signal is set
to zero speed.

1. IR COMP is set too high.

2. Control is in current

limit mode.

1. Motor armature leads

are reversed.

1. MIN SPD trimpot is not

adjusted properly.

1. Adjust the IR COMP

setting slightly CCW
until the motor speed
stabilizes (page 38).

2. Check that motor is of

sufficient horsepower
and amperage.

1. Reverse connections to

the motor armature.

1. Slowly rotate the MIN

SPD trimpot until the
motor stops.