1 easy and advanced modes, 2 viewing captured data – Teledyne LeCroy SierraNet M408 User Manual Ver.1.50 User Manual

Page 36

Advertising
background image

Teledyne LeCroy

Protocol Analyzer

34

 

SierraNet M408 User Manual

page 37.

) You can also open a .get

 

example file. Example files are in the Examples folder. 

You can also select File > Recent Projects to open a project you had recently saved.

Note:

Select File from the main menu Analyzer Menu Bar or click on the Hide Menubar icon 

 and 

select File > Open. Clicking the Alt key toggles showing/hiding the Analyzer Menu Bar.

Note:

The application prevents the host machine from going into sleep mode to avoid loss of traces.

The software menus and toolbar options are explained in detail in 

“Software Menus and 

Toolbar” on page 39

.

For more information on Analyzer Settings refer to 

“Analyzer Settings” on page 52.

1.7.1

Easy and Advanced Modes

Click on the Trigger/Filter Setting icon 

 located in the Trigger/Filter Settings pane 

under the main application toolbar to select Easy or Advanced mode.

In Easy Mode, select the Filter tab to select Capture EverythingFilter in Selected 
Patterns 
or Filter Out Selected Patterns. You can opt to Always Filter Out Idles or Ports 
and Truncate Payload in DWord(s). For Filter in Selected Patterns, select a Pattern from 
the left pane. You can exclude patterns and frames. You can do this by dragging patterns 
from the Patterns Library pane into the Active pane. You can use different patterns for 
pre‐trigger and post‐trigger.

In Easy Mode, on the Trigger tab, select the trigger type. Select a Pattern from the left 
pane as explained above.

Change the Analyzer settings if necessary. Change the port Speed if necessary. 

See 

“Trigger and Filter Settings in Easy Mode” on page 59.

Use Advanced Mode only after you become familiar with the hardware and software and 
have special needs. To start working with the protocol analyzer and software. For more 
information on Advanced Mode refer to 

“Advanced Mode (User‐Defined)” on page 141.

1.7.2

Viewing Captured Data

After data capture, the captured data is in the Viewer, see 

“Display Manipulation” on 

page 149. 

You can display the same data in:

Spreadsheet View: Shows Protocol Fields and Frames by time.

Frame Inspector View: Shows detail information about packet highlighted in 
Spreadsheet or Packet views.

Traffic Summary View: The Traffic Summary View for each captured signal can 
be viewed. It displays errors for the whole trace or for a selected range. You can 
show grid lines, select rows and modify columns.

Data View: The 

Data

View displays information in Hexadecimal and ASCII format.

Advertising