Sierra M122 SAS/SATA Protocol Analyzer User Manual
245
Scenario Actions
Teledyne LeCroy
To create an event using the captured DWORD, in the Event Properties menu, select SAS
Data Pattern (or SATA Data Pattern), and then select any of the 12 DWORDs (DWORD 0
Type through DWORD 11 Type). The drop‐down menu provides the choice of a custom
DWORD or any of the four captured DWORDs (see
). If you select
a captured DWORD, the Value field beneath this selection is hidden (the Value field is
only used for specifying custom DWORDs). Note that choice of a mask and an offset are
still available when using captured DWORDs.
Figure 4.18: Using a Captured DWORD in a SAS Data Pattern
Captured data DWORDs may also be used in the Substitute Data DWORD test state
action. From the Action Properties screen, choose Substitute Data DWORD and then
select the Substitute for property. A drop‐down menu is provided (see
)that allows the choice of a custom DWORD or any of the four captured DWORD
registers.