Creating a Sequence
264
Sierra M122 SAS/SATA Protocol Analyzer User Manual
Note that the states in this sequence have been renamed (do not have their default
names). The following table summarizes the sequence logic.
TABLE 4.10: Example 8: Logic of Sequence 0
1. Click the New Scenario button in the main library or one of the device libraries. In
the Scenario Properties dialog, enter the scenario name, description, and direction
of traffic change.
2. As in previous examples, create the five states for this sequence.
State
Description
Wait for Align (0)
When an Align (0) is received, go to Wait for Align (1).
Wait for Align (1)
If an Align (1) is received next, go to Wait for Align (2);
otherwise, go to Indicate Error.
Wait for Align (2)
If an Align (2) is received next, go to Wait for Align (3);
otherwise, go to Indicate Error.
Wait for Align (3)
If an Align (3) is received next, restart test;
otherwise go to Indicate Error.
Indicate Error
Indicate error and restart test.