Teledyne LeCroy Sierra M122 User Manual User Manual

Page 79

Advertising
background image

    

Sierra M122 SAS/SATA Protocol Analyzer User Manual

77

SAS/SATA Software Menus and Toolbars

  Teledyne LeCroy

Timeout

Selecting Timeout for the pattern opens the Timeout Pattern dialog.

Figure 2.39: Timeout Dialog

"Start Events" starts the timer in Timeout Trigger and "End Events" triggers the analyzer (if 
first trigger mode is selected) or resets the trigger (if second trigger mode is selected). 
Repetitions of the Start Events are ignored until the End Event is encountered or the timer 
expires.

Select a pattern for Start Events or End Events, enter a Timeout value, then select Trigger 
Mode: 

If End Events occur before timer expires

If timer expires before End Events

Note:

Timeouts can only be configured from the Timeout Pattern dialog. The Timeout Pattern dialog 

allows configuring other patterns as triggers in combination with timeouts. Other pattern dialogs 
do not allow configuration of timeouts.

External/Manual Trigger

To set up an external trigger click the External/Manual Trigger category (see 

Figure 2.40 

on page 78

).