Introduction, About qualiphy, About qphy-hdmi – Teledyne LeCroy QPHY-HDMI User Manual

Page 5: Required hardware

Advertising
background image

QPHY-HDMI Operator’s Manual

Introduction

About QualiPHY

QualiPHY is highly automated compliance test software meant to help you develop and validate
the PHY (physical-electrical) layer of a device, in accordance with the official documents
published by the applicable standards organizations and special interest groups (SIGs). You can
additionally set custom variables and limits to test compliance to internal standards.

QualiPHY is composed of a “framework” application that enables the configuration and control
of separate tests for each standard through a common user interface. Features include:

Multiple Data Source Capability: Connect to your X-Stream oscilloscope via LAN or

other interfaces.

User-Defined Test Limits: Tighten limits to ensure devices are well within the passing

region, even if subsequently measured with different equipment.

Flexible Test Results Reporting that includes XML Test Record Generation.

Understand a device performance distribution, or obtain process related information from
the devices under test.

About QPHY-HDMI

QPHY-HDMI is an automated test package performing all the normative, real-time oscilloscope
tests for sources in accordance with version 1.4 of the High Definition Multimedia Interface
Compliance Test Specification (HDMI).

The software can be run on any Teledyne LeCroy oscilloscope with at least 8 GHz bandwidth
(for testing clock rates above 148.5 MHz). The oscilloscope must also have the QualiPHY
software installed and the QPHY-HDMI software option activated.

Required Hardware

• Real-time Teledyne LeCroy oscilloscope with all required software installed.

Note: QPHY-HDMI tests are designed to run on WavePro/SDA/DDA 7Zi/ZI-A,
WaveMaster/SDA/DDA Zi/Zi-A, LabMaster 9Zi/Zi-A Series oscilloscopes with minimum
8GHz bandwidth. The HDMI test specification requires 8 GHz bandwidth for testing clock
rates above 148.5 MHz.

• SDAII or SDAIII oscilloscope software option. (SDAII / SDIII is standard on SDA model

oscilloscopes)

• 8 SMA Male to SMA Male cables
• 4 TF-HDMI-3.3V test adapters
• HDMI test fixture

For the most complete and up-to-date list, see the HDMI SIG website: http://www.hdmi.org