Introduction to Qualiphy DDR4

QPHY-DDR4 is an automated test package performing all of the real time oscilloscope in accordance
with JEDEC Standard No. JESD79-4. The standard is available on jedec.org.

The software can be run on any Teledyne LeCroy Zi Series oscilloscope with at least 8 GHz
bandwidth. The oscilloscope must also be equipped with the QPHY-DDR4 and SDAIII options.

Required Equipment

• Real time Teledyne LeCroy Oscilloscope with at least 8 GHz bandwidth. The minimum

recommended bandwidth for DDR4 is 13 GHz.


• QPHY-DDR4 (available on firmware 7.4.0.3 or later) and SDA III options
Note: SDAIII is included on all SDA and DDA oscilloscope models

o

The VirtualProbe option is required to perform de-embedding

• A minimum of three Dxx30-PS differential probes (a fourth probe is required for some probe

setups)