IMBA-9454G Motherboard

Page 167

BL:

Time-out value (Its unit-second is dependent on the item “Watchdog

Timer unit select” in CMOS setup).

Table B-1: AH-6FH Sub-function

Call sub-function 2 to set the time-out period of Watchdog Timer first. If the time-out value

is not zero, the Watchdog Timer starts counting down. When the timer value reaches zero,

the system resets. To ensure that this reset condition does not occur, calling sub-function

2 must periodically refresh the Watchdog Timer. However, the watchdog timer is disabled

if the time-out value is set to zero.

A tolerance of at least 10% must be maintained to avoid unknown routines within the

operating system (DOS), such as disk I/O that can be very time-consuming.

NOTE:

When exiting a program it is necessary to disable the Watchdog Timer,

otherwise the system resets.

Example program:


; INITIAL TIMER PERIOD COUNTER
;
W_LOOP:

MOV

AX, 6F02H

;setting the time-out value

MOV

BL, 30

;time-out value is 48 seconds

INT

15H

;
; ADD THE APPLICATION PROGRAM HERE
;
CMP

EXIT_AP, 1

;is the application over?

JNE

W_LOOP

;No, restart the application

Advertising