WAFER-945GSE 3.5" Motherboard
Page 83
The Slope PWM option can only be set if the CPU FAN Mode Setting option is set to
Automatic Mode. Use the Slope PWM option to select the linear rate at which the PWM
mode increases with respect to an increase in temperature. A list of available options is
shown below:
0.125
PWM
0.25
PWM
0.5
PWM
1
PWM
2
PWM
4
PWM
8
PWM
15
PWM
The following system parameters and values are shown. The system parameters that are
monitored are:
System Temperatures: The following system temperatures are monitored
o
CPU Temperature
o
System Temperature
Fan Speeds: The CPU cooling fan speed is monitored.
o
CPU Fan Speed
Voltages: The following system voltages are monitored
o
CPU Core
o
+1.05V
o
+3.30V
o
+5.00V
o
+12.0 V
o
+1.5V
o
+1.8V
o
5VSB