Page 89

The Temperature Limit of Full option can only be set if the FAN x Mode Setting option

is set to Automatic Mode. Use the Temperature Limit of Full option to select the CPU

temperature at which the cooling will reach full speed. To select a value, select the

Temperature Limit of Full option and enter a decimal number between 000 and 127. The

temperature range is specified below.

Minimum Value: 0°C

Maximum Value: 127°C

Fan Start PWM [070]

The Fan Start PWM option can only be set if the FAN x Mode Setting option is set to

Automatic Mode. Use the Fan Start PWM option to select the PWM the fan starts to

rotate with after the temperature specified in the Temperature 3 Limit of Start is

exceeded. To select a value, select the Fan Start PWM option and enter a decimal

number between 000 and 127. The temperature range is specified below.

PWM Minimum Mode: 0

PWM Maximum Mode: 127

Slope PWM [4 PWM]

The Slope PWM option can only be set if the FAN x Mode Setting option is set to

Automatic Mode. Use the Slope PWM option to select the linear rate at which the PWM

mode increases with respect to an increase in temperature. A list of available options is

shown below:

0 PWM

1 PWM

2 PWM

4 PWM

8 PWM

16 PWM

32 PWM

64 PWM