3 com5 d-sub pinout selection (j4), 4 com5 termination resistors (j5, j6), 7 lcd voltage settings (jp9) – IEI Integration PPC-5xxx-9455 v1.00 User Manual

Page 64: Table 4-14: com5 rs-422/485 tx select, Table 4-15: com5 rs-422/485 tx select, Table 4-16: lcd voltage settings, 7 lcd voltage settings (jp9) warning

Advertising
background image

PPC-5xxx-9455 Panel PC

Page 46

4.5.6.3 COM5 D-Sub Pinout Selection (J4)

Jumper J4 sets the external COM5 serial port as RS-232 or RS-422/485.

J4 DESCRIPTION

1-2, 4-5, 7-8, 10-11

RS-232

2-3, 5-6, 8-9, 11-12

RS-422/485

Table 4-14: COM5 RS-422/485 TX Select

4.5.6.4 COM5 Termination Resistors (J5, J6)

The termination resistors J5 and J6 can remedy communication errors for RS-422/485

setups with cables over 1.5 km in length

J5 J6 DESCRIPTION

Open

Open

No terminator resistor set

Closed

Closed

Termination resistor set

Table 4-15: COM5 RS-422/485 TX Select

4.5.7 LCD Voltage Settings (JP9)

WARNING:

Do not change these settings. They are set for the installed LCD panel.

Using different settings on the preinstalled monitor can destroy it.

The LCD setup sets the voltage and default monitor settings on the PPC-5xxx-9455.

JP9 LCD

Voltage

1-2

3.3 V

3-4 5

V

5-6 12

V

Table 4-16: LCD Voltage Settings