6 com5 rs-232/422/485 settings, 1 com5 rs-232/422/485 rx select (j2), 2 com5 rs-422/485 tx select (j3) – IEI Integration PPC-5xxx-9455 v1.00 User Manual

Page 63: Table 4-10: com4 ri and voltage selection jumper, Table 4-11: com5 ri and voltage selection jumper, Table 4-12: com5 rs-232/422/485 rx select, Table 4-13: com5 rs-422/485 tx select

Advertising
background image

PPC-5xxx-9455 Panel PC

Page 45

JP6 COM4

Pin-9

Setting

1-2

12 V

3-4

RI

5-6 5

V

Table 4-10: COM4 RI and Voltage Selection Jumper

JP8 COM5

Pin-9

Setting

1-2

12 V

3-4

RI

5-6 5

V

Table 4-11: COM5 RI and Voltage Selection Jumper

4.5.6 COM5 RS-232/422/485 Settings

To enable RS-232, RS-422 or RS-485 on COM5, all the following jumpers should be

setup.

4.5.6.1 COM5 RS-232/422/485 RX Select (J2)

Jumper J2 sets the COM5 serial port as RS-232, RS-422 or RS-485.

J2 DESCRIPTION

1-2

RS232 (default)

3-4 RS422

5-6 RS485

Table 4-12: COM5 RS-232/422/485 RX Select

4.5.6.2 COM5 RS-422/485 TX Select (J3)

Jumper J3 sets the COM5 serial port as RS-422 or RS-485.

J3 DESCRIPTION

1-3, 2-4

RS422

3-5, 4-6

RS485

Table 4-13: COM5 RS-422/485 TX Select