Imperial, Metric, Marking* – for all material thicknesses – Lincoln Electric 718118 Spirit II 400 User Manual

Page 101

Advertising
background image

Spirit II User’s Manual

Section 5: Torch Consumables and Cutting Charts

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

5-49

Stainless Steel - 150 Amps - Air Plasma / Nitrogen Shield

Silver Electrode

Shield Cap

Nozzle

Electrode

277117

279493

279420

(green o-ring)

Outer Cap

Retaining Cap

Swirl Ring

Torch Head

284150

277152

279439

279060

Imperial*

Material

Thickness

Preflow

Plasma

Shield

Postflow

Arc

Voltage

Travel

Speed

Cutting

Height

Pierce

Height

Pierce

Time

Kerf

Width

(in)

(psi)

(psi)

(psi)

(psi)

(volts)

(ipm)

(in)

(in)

(msec)

(in)

1/4

20

71

70

69

145

150

.160

.250

400

.125

3/8

150

115

.180

.275

500

1/2

155

85

.210

.300

600

.130

5/8

160

60

.220

.325

800

3/4

168

45

.240

.350

1200

.135

Metric*

Material

Thickness

Preflow

Plasma

Shield

Postflow

Arc

Voltage

Travel

Speed

Cutting

Height

Pierce

Height

Pierce

Time

Kerf

Width

(mm)

(psi)

(psi)

(psi)

(psi)

(volts)

(mm/m)

(mm)

(mm)

(msec)

(mm)

6

20

71

70

69

144

3910

4.0

6.3

400

3.2

10

150

2805

4.7

7.0

600

12

153

2330

5.1

7.4

3.3

16

160

1510

5.6

8.3

800

20

170

1030

6.2

9.0

1200

3.4

Marking* – For All Material Thicknesses

Type of Gas

Preflow Plasma

Shield

Postflow

Arc

Voltage

Travel

Speed

Marking

Height

Initial

Height

Pierce

Time

(Plasma) (Shield)

(psi)

(psi)

(psi)

(psi)

(volts)

(ipm) (mm/min) (in) (mm) (in) (mm) (msec)

Nitrogen Nitrogen

N/A

25

25

N/A

135

250

6350

.100 2.5 .100 2.5

0

Argon** Nitrogen**

N/A

50

25

N/A

65

100

2540

.100 2.5 .100 2.5

0

* Use an arc transfer height (ignition height) of .200” (5.1 mm) for cutting and .100” (2.5 mm) for marking.

** Only available on systems with the Automatic Gas Console.

(Revised 04/26/2013)

Advertising