Spirit II User’s Manual

Section 6: Maintenance &Troubleshooting

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

6-3

Impulse Start Console (ISC)

1. Open the cover (door) of the impulse start console and verify that all leads and

hoses are tightened securely.

Only tighten the fittings enough to make a water

or gas seal. The fittings are subject to damage if over tightened.


Work Ground

1. Verify that the work ground lead is securely fastened to the star ground on the

cutting table, and that the connection point is free from corrosion. Use a wire brush

to clean the connection point if necessary.