Imperial, Metric, Marking* – for all material thicknesses – Lincoln Electric 718118 Spirit II 400 User Manual

Page 86

Advertising
background image

Section 5: Torch Consumables and Cutting Charts

Spirit II User’s Manual

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

5-34

Stainless Steel - 400 Amps - Nitrogen Plasma / Air Shield

Copper Electrode

This gas combination gives medium cut quality and minimum dross levels

Shield Cap

Nozzle

Electrode

284155

284157

284159

Outer Cap

Retaining Cap

Swirl Ring

Torch Head

284150

284156

284122

279100

Imperial*

Material

Thickness

Preflow

Plasma

Shield

Postflow

Arc

Voltage

Travel

Speed

Cutting

Height

Pierce

Height

Pierce

Time

Kerf

Width

(in)

(psi)

(psi)

(psi)

(psi)

(volts)

(ipm)

(in)

(in)

(msec)

(in)

1/2

30

85

63

96

175

130

.210

.300

600

.165

5/8

170

110

.170

.350

800

3/4

165

90

.150

.400

1200

.200

1

170

65

.150

.500

1500

1.25

175

45

.160

.700

2000

1.5

180

35

.170

.800

2500

.205

1.75 ***

190

25

.190

.350

1500

2.00 ***

205

15

.210

.350

Metric*

Material

Thickness

Preflow

Plasma

Shield

Postflow

Arc

Voltage

Travel

Speed

Cutting

Height

Pierce

Height

Pierce

Time

Kerf

Width

(mm)

(psi)

(psi)

(psi)

(psi)

(volts)

(mm/m)

(mm)

(mm)

(msec)

(mm)

12

30

85

63

96

176

3415

5.5

7.3

600

4.2

16

169

2775

4.2

8.9

800

20

165

2190

3.8

10.5

1500

5.1

25

169

1690

12.5

32

175

1120

4.1

18.0

2000

38

179

895

4.2

20.2

2500

5.2

45 ***

190

610

4.8

7.8

1500

50 ***

203

410

5.2

8.9

Marking* – For All Material Thicknesses

Type of Gas

Preflow Plasma

Shield

Postflow

Arc

Voltage

Travel

Speed

Marking

Height

Initial

Height

Pierce

Time

(Plasma) (Shield)

(psi)

(psi)

(psi)

(psi)

(volts)

(ipm) (mm/min) (in) (mm) (in) (mm) (msec)

Nitrogen Nitrogen

N/A

25

25

N/A

107

250

6350

.100 2.5 .100 2.5

0

Argon** Nitrogen**

N/A

50

25

N/A

71

100

2540

.160 4.1 .100 2.5

0

* Use an arc transfer height (ignition height) of .300” (7.6 mm) for cutting and .100” (2.5 mm) for marking.

** Only available on systems with the Automatic Gas Console.

*** Edge start recommended.

(Revised 04/26/2013)

Advertising