CNC Machine Interface Connections

Perform the following steps to properly interface the Spirit system with a CNC cutting

machine. See the system schematic for additional information.
Plasma Start Input

The power supply requires a contact closure between P8 pins 3 and 4 to commence the

cutting or marking sequence. The sequence is terminated when the contacts are

opened. The contacts should be rated for 24VDC - 7.3mA.
Plasma Cut/Mark Input

The power supply requires a contact closure between P8 pins 1 and 2 to put the system

in plasma marking mode. Opening the contacts puts the system in cutting mode. The

operating mode should be selected prior to applying a start signal. The contacts should

be rated for 24VDC - 7.3mA.
Arc Hold Input

The power supply requires a contact closure between P8 pins 10 and 11 to inhibit arc

starting even though a plasma start signal has been applied to the unit. When the

contacts are opened, the arc is initiated. This feature is used to decrease cycle time by

allowing pre-cut gas and contact sequencing to occur simultaneously with initial torch

height positioning. The contacts should be rated for 24VDC - 7.3mA.
Motion Output

The power supply provides a maintained contact closure output between P8 pins 12

and 14 as long as an arc is maintained between the torch and the workpiece. The

motion contacts are rated for 24VDC – 10mA.
Remote On/Off Input

The power supply requires a maintained contact closure between P8 pins 5 and 6 to

energize the system from a remote location, provided that the OFF Button on the

manual gas console is released. Opening the contacts deenergizes the system. If the

remote on/off feature is not used, install a jumper between terminal block TB1 positions

7 and 8. The contacts should be rated for 24VAC – 10mA.
Power Supply Ready Output

The power supply provides a maintained contact closure output between P8 pins 7 and

8 when the system is ready to cut or mark. The contacts are open during gas purge or

when an error occurs. The contacts are rated for 24VDC – 10mA.