Imperial, Metric, Marking* – for all material thicknesses – Lincoln Electric 718118 Spirit II 400 User Manual

Page 99

Advertising
background image

Spirit II User’s Manual

Section 5: Torch Consumables and Cutting Charts

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

5-47

Mild Steel - 400 Amps - Oxygen Plasma / Air Shield

Silver Electrode

Shield Cap

Nozzle

Electrode

284123

284125

279460

(black o-ring)

Outer Cap

Retaining Cap

Swirl Ring

Torch Head

284150

284121

279422

279060

Imperial*

Material

Thickness

Preflow

Plasma

Shield

Postflow

Arc

Voltage

Travel

Speed

Cutting

Height

Pierce

Height

Pierce

Time

Kerf

Width

(in)

(psi)

(psi)

(psi)

(psi)

(volts)

(ipm)

(in)

(in)

(msec)

(in)

1/2

30

79

70

76

140

160

.140

.300

500

.150

5/8

145

135

.130

.350

600

.155

3/4

110

.400

800

.160

1

150

85

.160

.500

1000

.180

1.25

155

60

.175

.600

1500

.190

1.5

160

50

.225

.700

2000

1.75

162

40

.260

.800

3000

.200

2.00

165

33

.270

1.00

4500

.210

2.25 ***

170

20

.280

.350

1000

.235

2.50 ***

182

15

.300

.350

1300

.245

2.75 ***

185

12

.325

.350

1500

.245

3.00 ***

195

8

.350

.350

2000

.250

Metric*

Material

Thickness

Preflow

Plasma

Shield

Postflow

Arc

Voltage

Travel

Speed

Cutting

Height

Pierce

Height

Pierce

Time

Kerf

Width

(mm)

(psi)

(psi)

(psi)

(psi)

(volts)

(mm/m)

(mm)

(mm)

(msec)

(mm)

12

30

79

70

76

138

4205

3.6

7.3

500

3.8

16

145

3405

3.3

8.9

800

3.9

20

2700

3.4

10.5

1000

4.1

25

149

2200

4.0

12.5

4.6

32

155

1500

4.4

15.3

1500

4.8

38

159

1275

5.6

17.7

2000

45

162

995

6.6

20.5

3000

5.1

50

164

860

6.8

25.4

4500

5.3

55 ***

168

620

6.9

11.9

1000

6.0

60 ***

175

450

7.2

8.9

1300

6.2

65 ***

182

365

7.7

1500

70 ***

185

300

8.3

2000

6.4

75 ***

193

220

8.7

Marking* – For All Material Thicknesses

Type of Gas

Preflow

Plasma

Shield

Postflow

Arc

Voltage

Travel

Speed

Marking

Height

Initial

Height

Pierce

Time

(Plasma) (Shield)

(psi)

(psi)

(psi)

(psi)

(volts)

(ipm) (mm/min) (in) (mm) (in) (mm) (msec)

Nitrogen Nitrogen

N/A

25

25

N/A

112

250

6350

.100 2.5 .100 2.5

0

Argon**

Air**

N/A

50

25

N/A

53

100

2540

.120 3.0 .100 2.5

0

* Use an arc transfer height (ignition height) of .300” (7.6 mm) for cutting and .100” (2.5 mm) for marking.

** Only available on systems with the Automatic Gas Console.

*** Edge start recommended.

(Revised 04/26/2013)

Advertising