Setting up to cut – Lincoln Electric 718118 Spirit II 400 User Manual

Page 46

Advertising
background image

Section 4: Operation with Manual Gas Console

Spirit II User’s Manual

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

4-2

Setting up to Cut

The following procedure uses the information from the cutting charts in Section 5 to

prepare the system to cut. Press the UP or DOWN button on the MGC to move the

pointer through the menu as described below.

Push the

OFF Button on the MGC to disable

the system. On the main menu, move the

pointer to

Setup. Press SELECT.

Press SELECT to cycle through the list until

Cutting is displayed.

Move the pointer to

Current.

Press SELECT to cycle through the list until

the desired amperage is displayed.

Move the pointer to

Select Gas.

Press SELECT.

Press SELECT to choose the

Plasma gas.

Move the pointer to

Shield and press SELECT

to choose the shield gas. Move the pointer to

Return and press SELECT.

Move the pointer to

Adjust Gas.

Press SELECT.

Move the pointer to a gas and then press

SELECT to start the flow of that gas. Turn the

corresponding regulator knob on the MGC to

adjust the displayed pressure to match the

value in the cutting chart. Repeat for all other

gases. Move the pointer to

Return and press

SELECT. Repeat to return to the main menu.

The system is now setup to cut.