Setting up to Mark (Overrides Cut)

The system will automatically switch between cutting and marking based upon

commands in the part program. However, all cutting commands in the part program can

be overridden with marking commands by simply changing the

Process to Marking.

Push the

OFF Button on the MGC to disable

the system. On the main menu, move the

pointer to

Setup. Press SELECT.

Press SELECT to cycle through the list until

Marking is displayed. Move the pointer to

Return and press SELECT.

The system is now setup to mark instead of

cut.

Verifying Input Gas Pressures

For the system to work properly the input gas pressures must be within an acceptable

range. To check the input pressures, follow the steps below.

On the main menu, move the pointer to

Input Gas. Press SELECT.

Verify that all connected gas pressures are at

least 120psi. The maximum input gas pressure

is 145psi.

Press SELECT to return to the main menu.