Section 6: Maintenance &Troubleshooting

Spirit II User’s Manual

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

6-10

Problem

Possible Cause

Primary power has been

applied to the system, but

the manual gas console

screen is blank

1. Check power/communications CAN cable

connection on back of manual gas console.

2. Check for blown DIN rail fuse.

3. Check for 120v on pins of power/communications

CAN cable at back of the manual gas console.

The manual gas console

screen is on, but the screen

doesn't work

1. Cycle primary power to the Spirit system.

2. Check the connection of the ribbon cable that

connects the keypad to the DSP PCB in the

manual gas console.

Gas pressures will not adjust

properly

1. Wrong consumables installed in torch.

2. Loose pressure transducer cable on PC board in

the MGC.

3. Check connectors on the MGC valve associated

with the malfunction.

Low pressure error

1. Supply gas pressure(s) less than 120 psi.

Pressure error during cut

1. Supply gas pressure(s) fluctuating during cut.