3.

Referring to Connector/Jumper Layout diagram on the following

page, set all jumpers on the RLM main board according to the

specific application requirements. These settings affect the Tank

Monitor communications parameters such as baud rate, parity,

data bits and device addressing. Also, these jumpers allow the

RLM to be configured for daisy-chaining together using, RS485

multi-drop circuitry. Refer to Diagram: RLM (Mechanical)

Connector/Jumper Layout which follows.

4.

Mount pulsers on volume shaft of mechanical dispenser

computer. Refer to diagram on following page.

5.

Identify unused switch in electric reset for use as a return switch

on the RLM Mechanical. Refer to diagram on following page.

6.

Wire the pulsers and motor return (MR) switches to the RLM

Mechanical. Refer to Diagram: RLM (Mechanical)

Connector/Jumper Layout which follows.

7.

Connect a PC to the installed RLM’s communication cable.

8.

Plug the wall transformer into the dedicated power outlet to apply

power to the RLM system.

9.

Run Tester Program supplied on the system diskette shipped with

the RLM, and perform a preliminary test. Refer to Tester

Program, Preliminary Test, in the Diagnostics section of this

document.