Pump Specific Installation

RLM-S for Schlumberger SAM Electronic Dispenser

Note all warnings at the beginning of installation section.

The only Schlumberger dispensers supported by RLM-S are those
utilizing the SAM interface.

1.

Plug the adapter cable (supplied by PIE) for the Schlumberger
SAM into the adapter port on the RLM-S.

2.

Locate the SAM dispenser port and disconnect the existing
console/controller cable. Connect the RLM adapter cable to the
SAM dispenser port and the console/controller cable. Refer to
diagram on following page.

3.

Locate the dip switch in the SAM that determines the
communications baud rate for the dispenser port. Refer to the
Schlumberger SAM installation documentation and look up the
baud rate selected for this application.
Set the baud rate jumper
on the RLM-S to match the baud rate of the SAM.

The pump/hose positions reported by the RLM do not reflect the
product totals for physical pump/hose positions on the
Schlumberger pumps. The RLM stores all Schlumberger
transactions by product code. For additional details, see Table:
Product Codes, later in this section. Refer to the next page for
the diagram of a typical RLM-S installation.