Locate an unused position in the Gilbarco DBox and ensure that
the switch is in the ‘Isolate’ position. Connect the cut end into the
Gilbarco DBox at this position. At this point, move the switch to
the’Normal’ position. In the event that the DBox positions are
full, wire the RLM adapter cable in series with an existing pump.
Reference Diagram: RLM-G to Gilbarco DBox PA01330000..

3.

If the Gilbarco system employs a PA03060020 DBox, disconnect
the Gilbarco console/controller from the distribution box and
connect the Gilbarco style RLM adapter cable (PIE 9000 15
0027) to the Gilbarco DBox the DB9 to RJ45 adapters. Plug the
long end of the adapter cable into the RLM DB9P connector.
Reference Diagram: RLM-G to Gilbarco DBox PA03060000
following this section.

4.

If the Gilbarco system employs an RS422 style Universal DBox,
disconnect the Gilbarco console/controller from the DBox and
connect the Gilbarco style RLM adapter cable (PIE 9000 15
0028) to the Gilbarco DBox. Plug the long end of the adapter
cable into the RLM DB9P connector on the end of the RLM.
Reference Diagram: RLM-G to Gilbarco RS422 following this
section.

5.

On all RLM-Gs that attach to current loop style DBoxes, check
green LED D4 for reverse loop condition. If this LED is on,
rotate the harness on J4 180 degrees and replug. D4 should go
out and the red LED D3 should start flashing. See Diagnostics,
Pump Specific Troubleshooting, Gilbarco, for assistance.

6.

Return to the RLM General Installation for remaining system
installation procedures.