Diagnostics

Pump-Specific Troubleshooting

Gilbarco

PROBLEM

RECOMMENDATION

Reverse LED (D4) is on.

Rotate connector J4 on adapter board 180 degrees.

LED (D3) is off and never flashes.

Console/POS not communicating with pumps.

LED (D4) is on solid.

Adapter cable connected incorrectly.
Wrong type adapter communications input used
— RS422/current loop.
For current loop operation, connect adapter
harness to J4 and place jumper on J5. For RS422
operation, connect adapter harness to J3 and place
jumper on J2.
Defective cable.

All communications down on

Make sure the correct adapter cable is connected.

console/POS to pumps.

Adapter cable connected incorrectly.
Wrong type adapter communications input used
— RS422/current loop.
For current loop operation, connect adapter
harness to J4 and place jumper on J5. For RS422
operation, connect adapter harness to J3 and place
jumper on J2.
Defective cable.