<9. Parameter Lists>

9-4

IM 01C25T04-01EN

Relative

Index

Index

Parameter

Write

Mode

Initial Value

Explanation

25

41

PROCESS_

CONNECTION_TYPE

O/S

Unknown

Index code for the material of the process connection. The

coding is in accordance to the Material Codes given in

teneral Requirements.

26

42

PROCESS_

CONNECTION_

MATERIAL

O/S

Unknown

Material code for the type of process connection. The index

code is manufacturer specific.

27

43

TEMPERATURE

Temperature with the associated status used within the

transducer.

28

44

TEMPERATURE_

UNIT

O/S

1001: deg C

The unit of the temperature.

29

45

SECONDARY_

VALUE_1

Pressure value and status available to the Function Block.

30

46

SECONDARY_

VALUE_1_UNIT

O/S

kPa

Pressure unit of the SECONDARY_VALUE_1

33

49

LIN_TYPE

O/S

0: Linear

Type of linearization

0: Linear

1: Linearization table

10: Square root

34

50

SCALE_IN

AUTO

This is the input conversion using the high and low scale.

The related unit is the SECONDARY_VALUE_1_UNIT.

35

51

SCALE_OUT

AUTO

Output conversion of the linearized value using the high and

low scale. The related unit is the PRIMARY_VALUE_UNIT.

It is in accordance to the table of units codes given in the

general requirements.

36

52

LOW_FLOW_

CUTOFF

O/S

0

This is the point in percent of flow until the output of the flow

function is set to zero. It is used for suppressing low flow

values.

38

54

TAB_ACTUAL_

NUMBER

0

The actual numbers of entries in the table. It shall be

calculated after the transmission of the table is finished.

39

55

TAB_ENTRY

O/S

0

This parameter identifies which element of the table is in the

TAB_X_Y_VALUE parameter currently

40

56

TAB_MAX_NUMBER

31

Maximum size of the table in the device

41

57

TAB_MIN_NUMBER

2

Minimum size of the table in the device

42

58

TAB_OP_CODE

O/S

0: not initialized

The modification of a table in a device influences the

measurement or actuation algorithms of the device. This

parameter is to control the transaction of the table.

43

59

TAB_STATUS

0

Result of plausibility check in the device

44

60

TAB_X_Y_VALUE

O/S

One value couple of the table

59

75

PRIMARY_VALUE_

URL

100

Upper limit of primary value

60

76

PRIMARY_VALUE_

LRL

-100

Lower limit of primary value

61

77

SENSOR_SN

Serial number of sensor

62

78

SENSOR_CAL_

METHOD

O/S

103: Factory trim

standard calibration

The method of the last sensor calibration

100= volumetric

101= static weight

102= dynamic weight

103= factory trim standard calibration

104= user trim standard calibration

105= factory trim special calibration

106= user trim special calibration

255= other

63

79

SENSOR_CAL_LOC

O/S

Space

Set/indicate the location of the last sensor calibration

64

80

SENSOR_CAL_DATE O/S

Set/indicate the date of the last sensor calibration

65

81

SENSOR_CAL_WHO O/S

Space

Set/indicate the name of the person responsible for the last

sensor calibration

66

82

STATIC_PRESSURE_

HIGH_VALUE

67

83

STATIC_PRESSURE_

UNIT

O/S

kPa

Unit of static pressure

68

84

CAL_DEVIATION_HI

O/S

0

Deviation value for span adjustment

69

85

CAL_DEVIATION_LO O/S

0

Deviation value for zero adjustment

70

86

PRIMARY_VALUE_

FTIME

O/S

2

Damping time constant for primary value