3 lcd transducer block, Lcd transducer block -6 – Yokogawa EJX115A User Manual

Page 66

Advertising
background image

<9. Parameter Lists>

9-6

IM 01C25T04-01EN

Relative

Index

Index

Parameter

Write

Mode

Initial Value

Explanation

176

192

TEST_16

Not used for the transmitter

177

193

TEST_17

Not used for the transmitter

178

194

TEST_18

Not used for the transmitter

179

195

TEST_19

Not used for the transmitter

180

196

TEST_20

Not used for the transmitter

181

197

TEST_21

Not used for the transmitter

182

198

TEST_22

Not used for the transmitter

183

199

TEST_23

Not used for the transmitter

184

200

TEST_24

Not used for the transmitter

185

201

TEST_25

Not used for the transmitter

186

202

TEST_26

Not used for the transmitter

187

203

TEST_27

Not used for the transmitter

188

204

TEST_28

Not used for the transmitter

189

205

TEST_29

Not used for the transmitter

190

206

TEST_30

Not used for the transmitter

191

207

TEST_31

Not used for the transmitter

9.3 LCD Transducer Block

Relative

Index

Index

Parameter

Write

Mode

Valid

Range

Initial Value

Explanation

0

16

BLOCK_OBJECT

Information on this block such as Block Tag, DD

Revision, Executiion Time etc.

1

17

ST_REV

0

The revision level of the static data associated

with the function block. The revision value will be

incremented each time a static parameter value in

the block is changed.

2

18

TAG_DESC

AUTO

Space

The user description of the intended application of

the block.

3

19

STRATEGY

AUTO

0-65535

0

The strategy field can be used to identify grouping

of blocks. This data is not checked or processed by

the block.

4

20

ALERT_KEY

AUTO

0-255

0

The identification number of the plant unit. This

information may be used in the host for sorting

alarms, etc.

5

21

TARGET_MODE

AUTO

AUTO

Set the Target of block mode (MODE_BLK) to Auto,

Man or O/S according to the write Mode of the

parameter to be set or changed.

6

22

MODE_BLK

AUTO

The mode parameter is a structured parameter

composed of the actual mode, the normal mode,

and the permitted mode.

7

23

ALARM_SUM

The current alarm status associated with the

function block

8

24

DISPLAY_SEL

AUTO

0x00-0x0F 0x01

(DISPLAY1

ON)

Selection of display 1 to 4 to be shown on LCD

Bit0=1:DISPLAY1 ON

Bit1=1:DISPLAY2 ON

Bit2=1:DISPLAY3 ON

Bit3=1:DISPLAY4 ON

9

25

INFO_SEL

AUTO

0x00-0x0F 0x06

Selection of items to be displayed

Bit0=1:TAG ON

Bit1=1:PARAMETER ON

Bit2=1:UNIT ON

Bit3=1:STATUS ON

10

26

BLOCK_TAG1

AI1

Block tag which includes a parameter to be

displayed on display1

11

27

PARAMETER_SEL1

AUTO

0x010A: AI1.

OUT

Selection of a parameter to be displayed on

display1. Select a parameter from Table

12

28

DISPLAY_TAG1

AUTO

Space

Name of block tag to be displayed on display1; up to

six alphanumeric plus a slash[/] and a period [.]

Advertising