4 temperature curves, 4 temperature curves -15 – Yokogawa RAKD User Manual

Page 45

Advertising
background image

IM 01R01B30-00E-E 5th edition January 01, 2013 -00

<7. TECHNICAL DATA>

7-15

All Rights Reserved. Copyright © 2003, Rota Yokogawa

7.4 Temperature curves

50

55

60

65

70

75

100

200

Illustration of maximum allowable operation temperature depending on
ambient temperature for Rotameter type RAKD

Max. operation temperature [°C]

Ambient temperature [°C]

75

80

125

150

175

225

250

275

Version without valve

Version with valve

F6.EPS

Fig. 7-9

For option /KS1 or /KN1 (Ex-i-versions ATEX) the maximum values for ambient and process temperature according to
the respective temperature class mentioned in fig. 5 and table 7 must be regarded.
For option /ES1 (Ex-i-versions IECEx) the maximum values for ambient and process temperature according to the
respective temperature class mentioned table 9 must be regarded.
For option /NS1 (Ex-i-version NEPSI) the maximum values for ambient and process temperature according to the
respective temperature class mentioned in table 11 must be regarded.
The minimum ambient temperature is -25°C. Lower temperatures on request.

Advertising