Yokogawa RAKD User Manual

Page 55

Advertising
background image

<8. EXPLOSION-PROTECTED TYPE INSTRUMENTS>

8-9

IM 01R01B30-00E-E 5th edition January 01, 2013 -00

All Rights Reserved. Copyright © 2003, Rota Yokogawa

8.6 Intrinsically safe "ic" RAKD for Category 3G (ATEX

/IECEx) (/KS3, /ES3)

The RAKD with /KS3 or /ES3 is a unit with protection „ic”.
It may be used in hazardous areas of category 3G.
This version is same hardware as intrinsically safe "ia" type (/KS1, /ES1).

Data of electronic transmitter type -E :
Type of protection : Intrinsically safe Ex ic IIC T6-T4 Gc
Ambient temperature: -25°C ... +65°C
Safety relevant maximum values:
Supply (current output):
Maximum voltage:

U

i

= 30 V

Maximum current:

I

i

= 100 mA

Maximum power:

P

i

= 750 mW

Inner inductance:

L

i

= 0.73 mH

Inner capacity:

C

i

= 2.4 nF

Pulse output:
Maximum voltage:

U

i

= 16 V

Maximum current:

I

i

= 20 mA

Maximum power:

P

i

= 64 mW

Inner inductance:

L

i

= 0 mH

Inner capacity:

C

i

= 0 nF

Protection circuit for a power supply to meet the maximum values :

Data of limit switches :
Type of protection : Intrinsically safe Ex ic IIC T6 Gc
Safety relevant maximum values:

SC2-NO (/K1.../K3)

SJ2-S.N (/K6.../K10)

Type 2

Type 3

Type 2

Type 3

Maximale Spannung: U

i

= 16 V

16 V

U

i

= 16 V

16 V

Maximaler Strom:

I

i

= 25 mA

52 mA

I

i

= 25 mA 52 mA

Maximale Leistung:

P

i

= 64 mW

169 mW

P

i

= 64 mW 169 mW

Innere Induktivität:

L

i

= 0.15 mH

0.15 mH

L

i

= 0.1 mH 0.1 mH

Innere Kapazität:

C

i

= 150nF

150nF

C

i

= 30nF

30nF

current limitation

R1

S1 = 200 mA F


+

Po = 0.7 W

to

I o = 100 mA

D 1 = 27 V 5% 24V DC

U o = 28.35 V

“ic”

voltage -

C o= 260 nF

limitation

L o = 8.0 mH

-

R 1=

300 W, 5%, 3W

F2.EPS

RAKD

Advertising