4 non incendive rakd for category 3 (atex) (/kn1), 5 dust proofed limit switches (atex) (/ks2), 5 dust proofed limit switches (atex) (/ks2) -8 – Yokogawa RAKD User Manual

Page 54: Ii 3 gd, Ii 1 d

Advertising
background image

<8. EXPLOSION-PROTECTED TYPE INSTRUMENTS>

8-8

IM 01R01B30-00E-E 5th edition January 01, 2013 -00

All Rights Reserved. Copyright © 2003, Rota Yokogawa

8.4 Non incendive RAKD for Category 3 (ATEX) (/KN1)

Der RAKD with /KN1 is a unit with protection „nL”.
It may be used in hazardous areas of zone 2 (category 3)
The classification in brackets is given according to the EC- Directive ATEX, 94/9/EG.
This version is same hardware as intrinsically safe type.

Protection

: Ex nL IIC T6 X

n = non incendive

L = unit with limited energy

Explosion proof

: Ex nL IIC T6 X protection „n”; group II ; category 3GD

Marking

:

II 3 GD

Entity parameter :
Table 8-3

Analog output

Pulse output /CP

Limit switch

/K1 ... /K3

Limit switch

/K6 ... /K10

Ui [V]

30

16

16

16

Ii [mA]

100

20

25

25

Pi [mW]

750

64

64

64

Li [µH]

730

0

150

100

Ci [nF]

2.4

0

150

30

Protection circuit for a power supply to meet the maximum values :

8.5 Dust proofed limit switches (ATEX) (/KS2)

Certification by Pepperl & Fuchs :

EC-Type Examination Certificate Nr.: ZELM 02 ATEX 0128X
Identification in accordance with regulation 94/9/EG (ATEX) :

II 1 D

Type of protection

: Ex iaD 20

Maximum surface temperature

: 108°C.

The dust explosion proof for the limit switches is only available if ordered without electronic transmitter (only with
housing type "T").

current limitation

R1

S1 = 200 mA F


+

Po = 0.7 W

to

I o = 100 mA

D 1 = 27 V 5% 24V DC

U o = 28.35 V

“nL”

voltage -

C o= 260 nF

limitation

L o = 8.0 mH

-

R 1=

300 W, 5%, 3W

F1.EPS

RAKD

Ambient temperature : -25 °C < Ta < 65 °C :

Advertising