2 intrinsically safe atex certified rakd (/ks1), 1 technical data, 2 intrinsically safe atex certified rakd (/ks1) -2 – Yokogawa RAKD User Manual

Page 48: 1 technical data -2, Ii 2 g

Advertising
background image

<8. EXPLOSION-PROTECTED TYPE INSTRUMENTS>

8-2

IM 01R01B30-00E-E 5th edition January 01, 2013 -00

All Rights Reserved. Copyright © 2003, Rota Yokogawa

8.2 Intrinsically safe ATEX certified RAKD (/KS1)

8.2.1 Technical data

EC-Type Examination Certificate Nr.: KEMA 00ATEX1037X
Used standards:
- EN 60079-0: 2009
- EN 60079-11: 2007

The RAKD with electronic transmitter and limit switches is an intrinsically safe device. This device is certified for
hazardous areas of zone 1 (category 2) and zone 2 (category 3). It is not homologated for zone 0 (category 1).
The classifications in brackets are given according to EC- Directive 94/9/EG (ATEX).

Identification in accordance with regulation 94/9/EG (ATEX) :

II 2 G

Data of electronic transmitter type -E :
Type of protection : Intrinsically safe Ex ia IIC T6-T4 Gb
Ambient temperature: -25°C ... +65°C
Safety relevant maximum values:
Supply (current output):
Maximum voltage:

U

i

= 30 V

Maximum current:

I

i

= 100 mA

Maximum power:

P

i

= 750 mW

Inner inductance:

L

i

= 0.73 mH

Inner capacity:

C

i

= 2.4 nF

Pulse output:
Maximum voltage:

U

i

= 16 V

Maximum current:

I

i

= 20 mA

Maximum power:

P

i

= 64 mW

Inner inductance:

L

i

= 0 mH

Inner capacity:

C

i

= 0 nF

Data of limit switches :
Type of protection : Intrinsically safe Ex ia IIC T6 Gb
Safety relevant maximum values:

SC2-NO (/K1.../K3)

SJ2-S.N (/K6.../K10)

Type 2

Type 3

Type 2

Type 3

Maximum voltage:

U

i

= 16 V

16 V

U

i

= 16 V

16 V

Maximum current:

I

i

= 25 mA

52 mA

I

i

= 25 mA 52 mA

Maximum power:

P

i

= 64 mW

169 mW

P

i

= 64 mW 169 mW

Inner inductance:

L

i

= 0.15 mH

0.15 mH

L

i

= 0.1 mH 0.1 mH

Inner capacity:

C

i

= 150nF

150nF

C

i

= 30nF

30nF

Advertising