Yokogawa GC1000 Mark II Process Gas Chromatograph User Manual

Page 38

Advertising
background image

<6. OPC DA 2.0 Interface>

6-3

IM 11B06E01-01E

l

IREG (30001 to 39000)

Read only. Writing through the OPC interface does not cause an error, but nothing can be written

onto the Modbus area of ASGW/ASIU. Unmapped address data is always read as “0”.

OPC Data Name

OPC Data Type

Function

Remark

[email protected](n)

VT_UI2

Modbus Address 30001 to 31000

n = 1 to 1000

[email protected](n)

VT_UI2

Modbus Address 31001 to 32000

n = 1 to 1000

[email protected](n)

VT_UI2

Modbus Address 32001 to 33000

n = 1 to 1000

[email protected](n)

VT_UI2

Modbus Address 33001 to 34000

n = 1 to 1000

[email protected](n)

VT_UI2

Modbus Address 34001 to 35000

n = 1 to 1000

[email protected](n)

VT_UI2

Modbus Address 35001 to 36000

n = 1 to 1000

[email protected](n)

VT_UI2

Modbus Address 36001 to 37000

n = 1 to 1000

[email protected](n)

VT_UI2

Modbus Address 37001 to 38000

n = 1 to 1000

[email protected](n)

VT_UI2

Modbus Address 38001 to 39000

n = 1 to 1000

l

HREG (40001 to 49000)

Read/write is possible. Writing data onto unmapped areas is ignored. Do not write data onto the

DSCI-mapped address since the DCS may read wrong values until ASGW/ASIU reads the next

data from devices. Unmapped address data is always read as “0”.

OPC Data Name

OPC Data Type

Function

Remark

[email protected](n) VT_UI2

Modbus Address 40001 to 41000

n = 1 to 1000

[email protected](n) VT_UI2

Modbus Address 41001 to 42000

n = 1 to 1000

[email protected](n) VT_UI2

Modbus Address 42001 to 43000

n = 1 to 1000

[email protected](n) VT_UI2

Modbus Address 43001 to 44000

n = 1 to 1000

[email protected](n) VT_UI2

Modbus Address 44001 to 45000

n = 1 to 1000

[email protected](n) VT_UI2

Modbus Address 45001 to 46000

n = 1 to 1000

[email protected](n) VT_UI2

Modbus Address 46001 to 47000

n = 1 to 1000

[email protected](n) VT_UI2

Modbus Address 47001 to 48000

n = 1 to 1000

[email protected](n) VT_UI2

Modbus Address 48001 to 49000

n = 1 to 1000

NOTE

Although the input relay and input register are read-only data, they are not write protected in the

OPC interface. They should be engineered so that they are write protected from the OPC client

application. Otherwise, if ASGW/ASIU is connected to DCS, the value of input relay or input reg-

ister that has been accidentally written via the OPC interface may be read by the DCS.

4th Edition : Nov. 22, 2011-00

Advertising
This manual is related to the following products: