5 two geo s12 on wind-up stand, Required items, Procedure – Nexo LS18 User Manual

Page 50

Advertising
background image

Page 50/103

GEO

S12

HARDWARE SETUP PROCEDURE

8.4.5 Two GEO S12 on wind-up stand

Required items

1 x U” Bracket for two GEO S12 (GPT-PSBRK)

1 x Wind Up stand diameter 35mm (Eurotruss ES160 or equivalent);

IMPORTANT (WIND UP STAND)

- Wind Up stand must be rated for assembly weight (80kg rated load min);

- Wind Up stand must always be installed on a horizontal surface;

- Stand height and footprint must be defined to prevent assembly from collapsing;

- Ensure that public is not allowed within a safety area which radius is equal or higher
than assembly height.

Procedure

Set the 2 GEO S12 next to each other front grid to the floor

Slide GPT-PSBRK side plates into GEO S12s connecting plate oblong holes;

Lock safety pins into GEO S12s connecting plate;

IMPORTANT

Ensure that safety pins are properly locked into GEO S12s connecting panels.

Adjust inter-cabinet angle and lock to required angle value with 8x20quick release pins;

Position “U” bracket over these side plates; align centre holes;

Insert adjustment handles, adjust vertical angle and tight the handles to prevent GEO
S12s from rotating around “U” bracket;

Lift assembly on Wind Up stand

Advertising
This manual is related to the following products: