Pump outside tank option - close up, Unit in step 8. step 5 – align the rainbank, Cd e f – Davey RAINBANK WITH SUBMERSIBLE PUMP User Manual

Page 13

Advertising
background image

RAINW

AT

ER

SUPPL

Y

from discharge

of rainwater pum

p

Power to pump vi

a

3 pin socket - plug th

e

rainwater pump in here.

1" BSP

M

200m

m

200

m

m

TO

TO

ILETS

AND/O

R

LAUNDR

Y

(do not mix/cross-connec

t

with mains water supply

)

* Pressure Limiting Valve

MAINS

WA

TER SUPPL

Y

3/4" BSP

M

Incoming power

to RainBank

®

via 3 pin plug

3/4" BSP

M

Stop valv

e

200 Micron ‘Y’ Strainer

recommended but not

supplied.

WHERE MAINS PRESSURE EXCEEDS 900kPa.

A PLV*

MUST

BE FITTED TO INLET!

RainBan

k

®

MUST

BE INSTALLE

D

HORIZONTALLY AS ILLUSTRATED

.

Stop valve

20mm hol

e

puMp outsIDe tank

optIon - close up

24

13

Step 3

– plumb up your suction

plumbing ensuring that the lowest point

in the inlet pipe is at least 200mm below

the lowest water level and at least 100mm

above the base of the tank.

Step 4

– Install the float switch. check

that the float switch lead (9m long)

will reach the rainbank

®

. For greater

distances between your rainwater tank

and pump, a 10m float switch (top and

side entry) extension lead (Davey part

no. 14186) will need to be added. up

to 4 float switch extension leads can be

added between the pump and the rainwater

float switch lead. It is recommended that

the float switch extension lead/s are in a

protective cinduit.
the float end should be set up so it can

fall no lower than 100mm above the level

of the lowest point in the inlet pipe so the

pump will always be shut off well before it

can run dry or draw in air.

this is secured to the pump suction

pipe with cable ties. allow no more than

100mm of cable between the float and the

lowest cable tie.

the plug end should be plugged into the

float switch inlet on the underside of the

rainbank

®

unit in step 8.

Step 5

– align the rainbank

®

for easy

fitting to the plumbing.

Step 6

– connect rainbank

®

to the

pump.

Step 7

– connect rainbank

®

to the

plumbing.

Step 8

– connect all leads.

Step 9

– test the unit - page 21.

W

ARNING: DO NOT

FIT

CHECK V

AL

VES BETWEEN RAINBANK

®

, PUMP

AND

TANK, UNLESS PUMP

IS

ABOVE MAXIMUM W

A

TER LEVEL

OF

TANK.

IMPORTANT: ALL PIPEWORK AND OUTLET FITTINGS FROM RAINBANK

®

MUST BE LA-

BELLED TO AS3500. TANK MUST HAVE ISOLATION VALVE FITTED. DO NOT CONNECT WITH
CRIMPED FITTINGS.

100
100

100
100

C

D

E

F

A

D
E
B

A

D
E
B

Advertising