Warnings, Abo ve groun d opt ion, Two types of installation – Davey RAINBANK WITH SUBMERSIBLE PUMP User Manual

Page 5

Advertising
background image

6

6

1

2

5

1

2

3

In-tank Optio

n

Model No. KRBS1&

2

3

5

6

9

4

7

Above Ground Option

Model No. KRB1,2,3&4

9

4

Mains water supply

900kPa Maximu

m

1

3/4” BSP Male thread

2

3/4” BSP Male thread

3

Pump Power lead

4

RainBank

®

Power lead

5

Stop valv

e

W

arning

:

Do not reconnect with

mains water supply

Important:

All pipework and outle

t

fittings from RainBank

®

must

be labelled to AS/NZS 3500

6

Float switch

7

Manual start button

8

Rainwater supply via pump

9

8

8

32

5

WarnIngs

• before installing your rainbank

®

controller, please read all instructions

carefully as failures caused by

incorrect installation or operation are

not covered by the guarantee. Your

rainbank

®

controller is designed

to handle clean water. the system

should not be used for any other

purpose without specific referral to

Davey. the use of the system to

pump flammable, corrosive and other

materials of a hazardous nature is

specifically excluded.

• WarnIng: Water freezing inside

the rainbank

®

will damage the unit.

locate your rainbank

®

and pump

so that they are not susceptible to

freezing.

• rainbank

®

must be installed and

serviced by a licensed plumber.

• check with your local water authority

on water restrictions when your

rainwater tank is connected to mains

water.

• Do not enter a empty rainwater tank

- they may contain hazardous gases.

• secure all openings to the rainwater

tank to ensure it will not permit access

to children.

abo

Ve groun

D opt

Ion

Mo

Del

no.

krb

1,2,3&4

In

-t

ank

opt

Ion

Mo

Del

no.

krbs

1&2

tWo tYpes oF

InstallatIon

(see page 12)

(see page 14)

!

Installation Inside Buildings: to

cater for possible plumbing leaks or damage

to the rainbank

®

system components, the

installation must include an enclosure that will

capture any water spraying from the plumbing

or rainbank

®

system and direct it into a

properly constructed drain tray.

!

Note: When installing a rainbank

®

and/or associated pump system inside a

building, allowance for possible high pressure

leakage Must be made.

!

Note: In order to carry out routine

maintenance to the rainbank

®

Must be easily

accessible to the end user or home owner.

!

Note: If the supply cord is damaged, it

must be replaced by manufacturer, its service

agent or similarly qualified persons in order to

avoid a hazard.