• Failure to prime the submersible

pump prior to connection of the pump

to rainbank

®

can cause an air lock

that may prevent the pump operating

properly.

The following sections of the Type

1 installation instructions are

applicable to Type 2 installations.

Step 2

– Work out the position of your

rainbank

®

with regard to distance to

power. the float switch lead is not an

issue here.

Step 4

– align the rainbank

®

for easy

fitting to the plumbing and fit Davey wall

bracket if required.

Step 5

– connect rainbank

®

to your

submersible pump as per instructions on

page 25.

Step 6

– connect the rainbank

®

to the

plumbing as for Installation type 1 on

page 19.

Step 7

– connect all leads as per

Installation type 1 on page 20. there is

no float switch lead as this is fitted to the

submersible pump.

Step 8

– test the unit - page 21.

INSTAllATION TYPE 3

below ground tank with submersible

pump D42a/b & D53a/b

IMPORTANT

• under australian standard 3500

collecting/storing rainwater in a

partially buried tank is considered

a medium level hazard. even though

rainbank

®

has a built-in dual check

back flow valve, you may be required

to fit additional backflow protection

valves to satisfy this requirement –

check with your local council as to

their guidelines on rainwater tank

installation and backflow prevention.

there is no need for a separate float

switch as this comes attached to the

submersible pump and does not plug

into the rainbank

®

unit.

!

puMp InsIDe tank

optIon - close up

TO

TO

ILETS

AND/OR LAUNDR

Y

(do not mix/cross-connect with mains water supply)

MAIN

S

WA

TER SUPPL

Y

3/4" BSP

M

RAINW

ATE

R

SUPPL

Y

from discharge of auto submersibl

e

rainwater pum

p

Power to pump vi

a

3 pin socket - plug th

e

rainwater pump in here.

Incoming power

to RainBank

®

via 3 pin plug

3/4" BSP

M

1" BSP

M

Stop valv

e

200 Micro

n

‘Y’ Straine

r

* Pressure Limiting Valv

e

WHERE MAINS PRESSURE EXCEEDS 900kPa. A PLV*

MUST

BE FITTED TO INLET!

Mains In

To House

W

ARNING: DO NOT

INST

ALL

CHECK

V

AL

VES BETWEEN PUMP

AND RAINBANK

®

.

IMPORTANT: ALL PIPEWORK AND OUTLET FITTINGS FROM RAINBANK

®

MUST BE LA-

BELLED TO AS3500. DO NOT CONNECT WITH CRIMPED FITTINGS.

Advertising