Davey RAINBANK WITH SUBMERSIBLE PUMP User Manual

Page 7

Advertising
background image

IMPORTANT

because it involves mains water,

rainbank

®

may only be legally

installed by a licensed plumber.

ensure mains water pressure is

limited to 900kpa.

note: because the effects of seasonal

change etc. can cause the

pump and tank to move slightly

relevant to the home it is highly

recommended that discharge and/

or suction pipe lines be fitted with

flexible pipe, such as braided

hose, reinforced suction hose or

polythene pipe.

Different types of RainBank

®

Installations

there are different ways a rainbank

®

can

be installed depending on your rainwater

tank and pump configuration.

INSTAllATION TYPE 1 - PAgE 16

Tank:

above ground

Pump:

outside tank

Float switch:

must be installed inside

of tank

Pump Kit:

krb1,2,3&4

INSTAllATION TYPE 2 - PAgE 21

Tank:

above ground

Pump:

submersible inside tank

Float switch:

incorporated with pump

Pump Kit:

krbs1&2

INSTAllATION TYPE 3 - PAgE 22

Tank:

below ground

Pump:

submersible inside tank

Float switch:

incorporated with pumps

Pump Kit:

krbs1&2

Mains In

To House

Mains In

To House

FS

30

7

1. Pump not plugged in.

plug pump into base of rainbank

®

and rainbank

®

into power supply.

see page 20.
2. No power supply to pump.

contact electrician and have power

restored.
3. Float switch not connected to

RainBank

®

.

plug float lead into

base of rainbank

®

. the connection

lead is located next to the power lead

coming from the rainbank

®

. to

confirm the connection is correct,

depress ‘manual override’ button,

pump will start.
4. No water in tank.

check water level in tank.

5. Float switch located at water

tank is installed incorrectly.

check position of float. see page 16-19.
6. Mains water supply not

connected to RainBank.

rainbank

®

system must have a

pressurised water supply connected to

inlet. press ‘manual override’

button to simulate mains water

flowing.
7. Mains supply to RainBank

®

turned off.

turn on mains water

supply. press ‘manual override’

button to simulate mains water

flowing. pump will start is rain water

is available.

8. Pump is faulty.

to confirm if the fault is within the

pump, plug the pump directly into

power point and check to see if it

starts. If the pump starts plug the

pump back into the rainbank

®

and

continue fault finding. If the pump

does not start contact your supplier for

further advice.
9. Lead from float switch to pump

broken or damaged.

replace float and lead assembly.
10. Float switch defective.

contact your supplier for further

advice.
11. Mains water flow is too low.

ensure flow at most distant outlet is

above 5 litres per minute.

SYMPTOM: PUMP WIll NOT SWITCH ON

hoW to Install raInbank

®

!