Model no. krbs1&2, Pump inside tank option - overall – Davey RAINBANK WITH SUBMERSIBLE PUMP User Manual

Page 14

Advertising
background image

6

6

1

2

5

1

2

3

In-tank Option

Model No. KRBS1&2

3

5

6

9

4

7

Above Ground Option

Model No. KRB1,2,3&4

9

4

Mains water supply
900kPa Maximum

1

3/4” BSP Male thread

2

3/4” BSP Male thread

3

Pump Power lead

4

RainBank

®

Power lead

5

Stop valve

Warning:
Do not reconnect with
mains water supply

Important:
All pipework and outlet
fittings from RainBank

®

must

be labelled to AS/NZS 3500

6

Float switch

7

Manual start button

8

Rainwater supply via pump

9

8

8

puMp InsIDe tank

optIon - oVerall

MoDel no. krbs1&2

14

23

You should carry out the following

steps as per the instructions for

Installation Type 1

Step 2

– Work out the position of your

rainbank

®

with regard to distance to

power. the float switch lead is not an

issue here.

Step 4

– align the rainbank

®

for easy

fitting to the plumbing. Fit Davey wall

bracket.

Step 5

– connect rainbank

®

to your

submersible pump as per instructions on

page 25.

Step 6

– connect the rainbank

®

to the

plumbing.

Step 7

– connect all leads (no float

switch lead to plug in)

Step 8

– test the unit - page 21

INSTAllATION TYPE 4

Below ground tank with pump above

tank and suction lift

IMPORTANT

• under australian standard 3500

collecting/storing rainwater in a

partially buried tank is considered

a medium level hazard. even though

rainbank

®

has a built-in dual check

back flow valve you may be required to

fit additional backflow protection

valves to satisfy this requirement.

note: to allow for the correct operation

of your rainbank

®

and for

movement of the tank and pump

which may occur over time, the

suction pipe must have a length of

flexible suction hose from pump

to top of tank. this hose can be

braided hose, reinforced suction

hose or polythene pipe at least 1

metre in length.

The following sections of the Type

1 installation instructions are

applicable to Type 4 installations.

Step 1

– evaluate and select the best

pump site as close to the water source

and water level as possible.

Step 2

– Work out the position of your

rainbank

®

with regard to distance to

power.

!

6

6

1

2

5

1

2

3

In-tank Option

Model No. KRBS1&2

3

5

6

9

4

7

Above Ground Option

Model No. KRB1,2,3&4

9

4

Mains water supply
900kPa Maximum

1

3/4” BSP Male thread

2

3/4” BSP Male thread

3

Pump Power lead

4

RainBank

®

Power lead

5

Stop valve

Warning:
Do not reconnect with
mains water supply

Important:
All pipework and outlet
fittings from RainBank

®

must

be labelled to AS/NZS 3500

6

Float switch

7

Manual start button

8

Rainwater supply via pump

9

8

8

FV

Mains In

To House

Advertising
This manual is related to the following products: