Figure 9, Rs-300 door, Wiring diagram – Hired-Hand RS-300 Door User Manual
Page 14
Part No. 4801-5157 Rev 11-05
RS-300 Door
Page 14 of 30
7.3
Setting Limit Switches on the Somfy Tube Motor Option
NOTE: These instructions apply to a motor mounted on the right-hand side of a curtain as viewed from the front.
OPEN and CLOSE directions of motor rotation are shown in Figure 10.
Close
Direction
Direction motor
rotates to roll down
curtain.
Open
Direction
Direction motor
rotates to roll up
curtain.
Fig. 10 Limit Switches (Motor mounted on the right-
hand side of curtain as viewed from front)
Figure 9
Wiring Diagram
NOTE: These instructions apply to a Somfy Tube Motor mounted on the right-
hand side of door. In this wiring diagram the motor turns in the
direction shown in Figure 8 to close the curtain. The motor turns in
the opposite direction to open the curtain.
Somfy
Motor
Ground(Green)
Open (Black)
Close (Red)
Neutral (White)
Ground Screw In Door
Terminal Block
Inside Motor Box
Ground(Green)
Close (Red)
Neutral (White)
Open (Brown)
Open (Black)
Black
Black - L1
Brown - B1
Red - A1
Green - Gnd
SWITCH
See Wiring Diagram
Inside Switch Package
120 Volt Line
Line
Ground
Neutral