8.2

Installation of Manaras Operator

The Manaras Operator has two sets of mounting holes: outside the frame for wall mounting and inside the frame for
hood mounting.

To open the control box cover, loosen the screw at the base of the cover. If the cover cannot be fully opened, the
retaining cam may be used to hold the cover in other positions. Refer to Figure 13, Control Box Cover Opening.




















After installation, verify that there is no obstacle in the way when opening the control box cover. If an obstacle
exists preventing the cover from opening, it is possible to remove the cover by cutting the plastic hinge at its thinnest
point or unscrewing it from the box before putting the operator on the wall or hood. Closing the cover will also
require using two supplementary screws. Refer to Figure 14, Hinge Elimination And Cover Fastening By
Screws.

























Figure 13

Control Box Cover Opening

Cut the hinge

lengthwise.

Remove the two

screws

Replace two
screws to fix

the cover.

Figure 14

Hinge Elimination And Cover Fastening By Screws